X
WhatsApp:15737324202
ALUMINUM CONDUCTOR ALLOY REINFORCED(ACAR)
ALUMINUM CONDUCTOR ALLOY REINFORCED(ACAR)

ALUMINUM CONDUCTOR ALLOY REINFORCED(ACAR)

An outer layer of Aluminum conductor concentrically stranded over the central core of solid Aluminum alloy or stranded Aluminum alloy wire to form ACAR conductor.
Construction
Technical Specifications
Quality Control
Application

Construction

Aluminum Conductor Alloy Reinforced

Standard

ASTM B524/B524M.

Technical Specifications

Aluminum Conductor Alloy Reinforced
ASTM B524/B524M
Size Nº of 1350
wires/mm
Nº of 6201
wires/mm
Overall cable diameter Mass Rated strength Nominal dc resistance at
20 °C
Ampacity
AWG mm² mm kg/km kgf Ω/km Sun. no wind Sun and wind No sun and wind
4 21.1 4/1.96 3/1.96 5.88 58.22 507.5 1.4757 81 135 141
2 33.63 4/2.47 3/2.47 7.42 92.55 793.8 0.9282 111 180 189
1/0 53.51 4/3.12 3/3.12 9.36 147.3 1221.9 0.5833 153 241 255
2/0 67.44 4/3.50 3/3.50 10.51 185.6 1502.5 0.4628 179 278 296
3/0 85.03 4/3.93 3/3.93 11.8 234 1861.4 0.3671 211 322 343
195.7 99.16 4/4.25 3/4.25 12.74 272.9 2170.9 0.3148 234 355 379
4/0 107.22 4/4.42 3/4.42 13.25 295.1 2347.3 0.2911 247 373 398
250 126.68 12/2.91 7/2.91 14.57 348.8 2813.8 0.2442 280 417 447
300 152.01 12/3.20 7/3.20 15.96 418.6 3344 0.2035 317 467 502
350 177.35 15/3.45 4/3.45 17.24 488.7 3390 0.1704 356 520 560
350 177.35 12/3.45 7/3.45 17.24 488.3 3816 0.1744 353 515 555
355 179.88 12/3.47 7/3.47 17.36 495.3 3871 0.1720 356 519 560
392.5 198.88 24/2.62 13/2.62 18.3 547.7 4277 0.1551 382 554 598
400 202.68 12/3.69 7/3.69 18.4 558.1 4318 0.1526 387 560 606
450 228.02 12/3.91 7/3.91 19.54 627.8 4810 0.1357 419 603 653
450 228.02 18/2.80 19/2.80 19.61 627.3 5401 0.1387 416 597 647
450 228.02 15/3.91 4/3.91 19.54 628.4 4240 0.1325 423 609 659
465.9 236.08 12/3.98 7/3.98 19.89 650 4980 0.1310 430 616 668
465.9 236.08 18/2.85 19/2.85 19.95 649.5 5592 0.1339 426 611 662
500 253.35 12/4.12 7/4.12 20.6 697.6 5344 0.1221 451 644 698
500 253.35 18/2.95 19/2.95 20.7 697 6001 0.1248 447 638 693
500 253.35 30/2.95 7/2.95 20.7 698.3 4901 0.1189 456 651 706
500 253.35 24/2.95 13/2.95 20.7 697.7 5395 0.1218 451 644 699
550 278.69 18/3.10 19/3.10 21.68 766.7 6556 0.1135 478 678 737
550 278.69 15/4.32 4/4.32 21.61 768 5183 0.1084 486 689 749
600 304.02 18/3.23 19/3.23 22.64 836.4 7152 0.1040 506 714 777
600 304.02 24/3.24 13/3.24 22.64 837.2 6409 0.1015 512 723 787
650 329.36 18/3.37 19/3.37 23.57 906.1 7534 0.0960 536 753 821
650 329.36 24/3.37 13/3.37 23.57 907 6798 0.0937 541 761 829
700 354.7 30/3.49 7/3.49 24.46 977.6 6680 0.0849 573 802 876
700 354.7 18/3.49 19/3.49 24.46 975.9 8114 0.0891 562 786 858
700 354.7 24/3.49 13/3.49 24.46 976.7 7240 0.0870 568 794 867
739.8 374.86 18/3.59 19/3.59 25.14 1031 8514 0.0844 584 815 890
750 380.03 33/3.62 4/3.62 25.31 1048 6525 0.0783 606 843 922
750 380.03 30/3.62 7/3.62 25.31 1047 7056 0.0793 603 839 918
750 380.03 18/3.62 19/3.62 25.31 1046 8631 0.0832 591 823 900
750 380.03 24/3.62 13/3.62 25.31 1046 7763 0.0812 597 831 909
800 405.37 18/3.74 19/3.74 26.14 1115 9207 0.0780 617 855 936
800 405.37 24/3.74 13/3.74 26.14 1116 8280 0.0761 623 864 946
850 430.7 18/3.85 19/3.85 26.95 1185 9711 0.0734 642 888 973
850 430.7 24/3.85 13/3.85 26.95 1186 8706 0.0716 649 897 983
853.7 432.58 24/3.86 13/3.86 27.01 1191 8744 0.0713 651 900 986
853.7 432.58 30/3.86 7/3.86 27.01 1192 7917 0.0696 658 909 996
900 456.04 18/3.96 19/3.96 27.7 1255 10283 0.0693 667 920 1009
900 456.04 24/3.96 13/3.96 27.73 1256 9219 0.0677 674 929 1019
900 456.04 30/3.96 7/3.96 27.7 1257 8347 0.0661 681 938 1029
918 465.16 18/4.00 19/4.00 28 1280 10488 0.0680 677 931 1022
927.2 469.82 18/4.02 19/4.02 28.1 1293 10593 0.0673 681 937 1028
950 481.37 18/4.07 19/4.07 28.49 1324 10854 0.0657 693 951 1044
950 481.37 30/4.07 7/4.07 28.5 1327 8810 0.0626 706 970 1065
950 481.37 24/4.07 13/4.07 28.49 1326 9731 0.0641 699 960 1055
1000 506.71 18/4.18 19/4.18 29.23 1394 11425 0.0624 717 981 1079
1000 506.71 54/3.25 7/3.25 29.27 1397 8890 0.0588 734 1005 1105
1000 506.71 30/4.18 7/4.18 29.23 1397 9274 0.0594 732 1002 1101
1000 506.71 42/3.25 19/3.25 29.27 1396 10211 0.0605 726 994 1092
1000 506.71 33/3.25 28/3.25 29.27 1394 10981 0.0619 720 985 1083
1024.5 519.12 30/4.23 7/4.23 29.59 1431 9501 0.0580 743 1016 1117
1024.5 519.12 18/4.23 19/4.23 29.59 1429 11707 0.0609 729 996 1096
1024.5 519.12 24/4.23 13/4.23 29.59 1430 10494 0.0594 736 1006 1106
1080.6 547.55 24/4.34 13/4.34 30.39 1508 11069 0.0563 762 1039 1144
1080.6 547.55 18/4.34 19/4.34 30.39 1506 12346 0.0578 755 1029 1133
1100 557.38 24/4.38 13/4.38 30.66 1535 11267 0.0554 772 1050 1157
1100 557.38 18/4.38 19/4.38 30.66 1533 12568 0.0567 764 1040 1146
1100 557.38 30/4.38 7/4.38 30.66 1536 10201 0.0540 779 1061 1168
1100 557.38 48/3.41 13/3.41 30.7 1536 10408 0.0542 778 1059 1167
1100 557.38 42/3.41 19/3.41 30.7 1535 11232 0.0550 774 1053 1160
1172 593.86 18/4.52 19/4.52 31.64 1634 13390 0.0532 797 1081 1192
1198 607.04 30/4.57 7/4.57 31.99 1673 11110 0.0496 824 1116 1232
1198 607.04 24/4.57 13/4.57 31.99 1672 12271 0.0508 817 1106 1220
1200 608.05 18/4.57 19/4.57 32.02 1673 13710 0.0520 810 1096 1210
1200 608.05 24/4.57 13/4.57 32.02 1674 12292 0.0507 817 1106 1220
1200 608.05 30/4.57 7/4.57 32.02 1676 11129 0.0495 825 1118 1233
1200 608.05 48/3.56 13/3.56 32.06 1676 11202 0.0497 825 1117 1232
1250 633.38 30/4.67 7/4.67 32.68 1746 11592 0.0476 848 1146 1265
1250 633.38 48/3.64 13/3.64 32.72 1746 11668 0.0477 847 1144 1264
1250 633.38 54/3.64 7/3.64 32.72 1746 10933 0.0470 852 1151 1271
1250 633.38 33/3.64 28/3.64 32.72 1743 13615 0.0495 835 1128 1246
1300 658.72 42/3.71 19/3.71 33.37 1814 13126 0.0466 864 1165 1288
1300 658.72 18/4.76 19/4.76 33.33 1812 14853 0.0480 854 1151 1272
1300 658.72 30/4.76 7/4.76 33.33 1816 12056 0.0457 870 1173 1296
1303 660.24 54/3.04 37/3.04 33.43 1818 14367 0.0471 861 1160 1283
1361.5 689.88 54/3.79 7/3.79 34.15 1902 11908 0.0432 900 1209 1338
1400 709.39 33/3.85 28/3.85 34.63 1952 15123 0.0442 900 1207 1336
1400 709.39 48/3.85 13/3.85 34.63 1955 12890 0.0426 913 1224 1355
1400 709.39 42/3.85 19/3.85 34.63 1954 13976 0.0432 907 1217 1348
1400 709.39 54/3.85 7/3.85 34.63 1956 12044 0.0420 918 1231 1363
1500 760.06 33/3.98 28/3.98 35.85 2092 16203 0.0413 941 1257 1394
1500 760.06 42/3.98 19/3.98 35.85 2093 14974 0.0404 949 1268 1406
1600 810.73 42/4.11 19/4.11 37.02 2233 15973 0.0378 990 1317 1463
1600 810.73 54/4.11 7/4.11 37.02 2235 13764 0.0368 1000 1332 1479
1700 861.4 42/4.24 19/4.24 38.16 2373 16971 0.0356 1029 1364 1517
1700 861.4 33/4.24 28/4.24 38.16 2371 18363 0.0364 1020 1353 1504
1703 862.92 42/4.24 19/4.24 38.2 2377 17001 0.0355 1030 1366 1519
1800 912.07 42/4.36 19/4.36 39.27 2512 17969 0.0336 1067 1410 1570
1800 912.07 33/4.36 28/4.36 39.27 2510 19701 0.0344 1058 1398 1557
1900 962.74 42/4.48 19/4.48 40.34 2652 18968 0.0319 1104 1454 1621
2000 1013.41 42/4.60 19/4.60 41.39 2791 19966 0.0303 1139 1497 1670
2250 1140.09 54/4.00 37/4.0 43.93 3169 23572 0.0276 1219 1590 1780
2493 1263.22 54/4.20 37/4.20 46.25 3512 26118 0.0249 1297 1681 1886
2500 1266.77 54/4.21 37/4.21 46.31 3521 26191 0.0248 1299 1683 1889
2750 1393.45 54/4.42 37/4.42 48.57 3874 28811 0.0225 1373 1770 1990
3000 1520.1 54/4.61 37/4.61 50.73 4226 31430 0.0207 1443 1850 2085

Quality Control

Aluminum Conductor Alloy Reinforced
Raw Material Testing

Raw Material Testing

NPC has always chosen raw material suppliers who have a good reputation, possess stable supply capabilities and have passed international quality system certifications (such as ISO 9001). And establish a long-term cooperative relationship with it, forming a stable and reliable raw material supply chain.
We will ensure that all raw materials are subject to strict inspection procedures upon entry to the factory, and can only be stored in the warehouse after they have been confirmed to meet the standards.
Process Inspection

Process Inspection

NPC has strict quality control procedures for each process in the cable production process.
Process documents: Develop detailed process flow and operation instructions to clarify the operating specifications and quality standards of each process.
Equipment calibration: Regularly calibrate key equipment such as wire drawing machines, stranding machines, extruders, and diameter gauges to ensure that the accuracy meets the requirements.
First piece confirmation: Before each batch of production, the first piece is trial-produced to confirm that the process parameters, product dimensions, electrical performance, etc. meet the standards before mass production can be carried out.
Finished Product

Finished Product

Inspectors conduct ex-factory inspections on cables according to relevant standards and corresponding product inspection specifications to ensure that each ex-factory product complies with the process regulations.

Application

ACAR conductors are used as bare overhead conductor for power transmission and distribution lines,where higher capacity and strength for equal weight are prime line considerations.ACAR is the solution over ACSR due to its better strength to weight ratio.

Factory View

● 30+ years of manufacturing experience
● ISO and UL certified production
● Customized cable and transformer solutions

Product Packaging

Packaging and delivery site
Packaging and delivery site
Packaging and delivery site
Packaging and delivery site
Packaging and delivery site
Packaging and delivery site
Packaging and delivery site
Packaging and delivery site
Packaging and delivery site
Packaging and delivery site
Packaging and delivery site
Packaging and delivery site
Packaging and delivery site
Packaging and delivery site
Packaging and delivery site
Packaging and delivery site

Related Products

FAQ From Customers

What are the advantages of power cables and overhead lines?
(1) Reliable operation, because it is installed in a hidden place such as underground, it is less damaged by external forces, has less chance of failure, and the power supply is safe, and it will not cause harm to people;
(2) The maintenance workload is small and frequent inspections are not required;
(3) No need to erect towers;
(4) Help improve power factor.
Which aspects should be considered when choosing the cross section of a power cable?
(1) The long-term allowable working current of the cable;
(2) Thermal stability once short circuited;
(3) The voltage drop on the line cannot exceed the allowable working range.
What are the measures for cable fire prevention?
(1) Use flame-retardant cables;
(2) Use fireproof cable tray;
(3) Use fireproof paint;
(4) Fire partition walls and fire baffles are installed at cable tunnels, mezzanine exits, etc.;
(5) Overhead cables should avoid oil pipelines and explosion-proof doors, otherwise local pipes or heat insulation and fire prevention measures should be taken.
What should be paid attention to during the transportation and handling of cables?
(1) During transportation, loading and unloading, cables and cable reels should not be damaged. It is strictly forbidden to push the cable reels directly from the vehicle. Generally, cables should not be transported and stored flat.
(2) Before transporting or rolling the cable reel, ensure that the cable reel is firm, the cable is wound tightly, the oil pipe between the oil-filled cable and the pressure oil tank should be fixed without damage, the pressure oil tank should be firm, and the pressure indication should meet the requirements.
What inspections should be carried out for the acceptance of cable lines?
(1) The cable specifications should meet the regulations, the arrangement should be neat, no damage, and the signs should be complete, correct and clear;
(2) The fixed bending radius of the cable, the related distance and the wiring of the metal sheath of the single-core power cable should meet the requirements;
(3) The cable terminal and the middle head should not leak oil, and the installation should be firm. The oil pressure of the oil-filled cable and the meter setting should meet the requirements;
(4) Good grounding;
(5) The color of the cable terminal is correct, and the metal parts such as the bracket are completely painted;
(6) There should be no debris in the cable trench, tunnel, and bridge, and the cover should be complete.
How many projects can cable engineering be divided into?
(1) Construction site transportation: including the loading and unloading, transportation and empty vehicle return journey of engineering materials from the warehouse to the construction site.
(2) Local engineering: including road excavation, tunnel, trench construction, etc.
(3) Laying engineering: including laying, intermediate head production, lift cover plate, buried pipe, school tide, tractor head production, etc.
(4) Two-end engineering: including the production and installation of support, suspension bridge and its foundation, the production of terminal heads, the installation of oil pressure and signal devices, and the electrical performance testing of various types.
(5) Stopping works: including the production of oil-filled cable stop heads, the installation of fuel supply tanks, automatic drainage and signal devices, etc.
(6) Grounding engineering: including installation of insulation joints, transposition boxes, protectors, and grounding boxes.
What tests and inspections should be carried out on power cables before laying?
Before laying, check whether the type, specification and length of the cable meet the requirements and whether there is external force damage. Low-voltage cables use a 1000V megohmmeter to remotely measure the insulation resistance, and the resistance is generally not less than 10MΩ. High-voltage cables use a 2500V megger to measure the resistance. Generally not less than 400MΩ.
What are the factors that determine the long-term allowable current carrying capacity of the cable?
(1) The long-term allowable working temperature of the cable;
(2) The heat dissipation performance of the cable itself; (3) The condition of the cable installation and the heat dissipation conditions of the surrounding environment.
According to the difference of insulation and protective layer, what are the main types of commonly used low-voltage power cables?
(1) Oil-impregnated paper insulated lead-clad (or aluminum-clad) power cable;
(2) Non-drip oil-impregnated paper insulated power cable;
(3) PVC insulated and sheathed power cable;
(4) Cross-linked PVC insulated and PE sheathed power cable;
(5) Cross-linked PVC insulated and sheathed power cable;
(6) Rubber insulated power cables.
What are the requirements for the fire blocking of cable holes?
For larger cable penetration holes, such as the cable penetration floor, etc., when using fireproof blocking materials to block, according to the actual situation, first coat four to six layers of fireproof paint on the cable surface, the length is about 1.5m below the hole, and then use fire-resistant The material is processed into a board-supporting fire-proof blocking material with a certain strength to ensure that it is firm after being blocked and is easy to disassemble and assemble when the cable is replaced. The plugging is dense and non-porous to effectively block smoke and fire.
What are the main properties of the insulation material of the power cable?
(1) High breakdown strength;
(2) Low dielectric loss;
(3) Very high insulation resistance;
(4) Excellent discharge resistance;
(5) It has certain flexibility and mechanical strength;
(6) Long-term insulation performance is stable.
What are the regulations for cable protection tubes?
(1) When the cable needs to be laid through a protective pipe, the inner diameter of the pipe should not be less than 1.5 times the outer diameter of the cable, and the inner diameter of the concrete pipe, clay pipe, asbestos, and cement pipe should not be less than 100mm;
(2) The bending radius of the cable tube should meet the requirements of the bending radius of the cable inserted;
(3) Each pipe should not exceed three elbows at most, and there should be no more than two right-angle bends.
How to measure the outer diameter of the cable sheath?
At five evenly distributed points on the circumference of the sheath, measure the outer diameter of the sheath and its average value. The average outer diameter is the outer diameter of the sheath.
How to connect copper core cables with different cross-sections?
Copper core cables with different cross-sections can be connected by open-back weak copper pipes and connected by soldering, or pure copper rods can be connected into copper pipes according to different cross-sectional requirements and connected by crimping.
What are the insulating materials used to make cable terminal heads or intermediate joints?
There are insulating glue, insulating tape, insulating tube, insulating gloves, insulating resin, etc.

Welcome your inquiry

Honesty, Integrity, Frugality, Activeness and Passion